구조단열패널 적용 저에너지주택의 총에너지사용량 평가
(주)코리아스칼라
- 최초 등록일
- 2016.05.03
- 최종 저작일
- 2013.06
- 10페이지/ 어도비 PDF
- 가격 4,000원
* 본 문서는 배포용으로 복사 및 편집이 불가합니다.
서지정보
ㆍ발행기관 : 한국복합신소재구조학회
ㆍ수록지정보 : 복합신소재구조학회 논문집 / 4권 / 2호
ㆍ저자명 : 이현주, 나환선, 조혜진, 최성모
목차
1. 서 론
2. 구조단열패널 에너지성능평가
3. CO₂배출량 분석
4. 생애주기 경제성 분석
5. 결 론
References
영어 초록
This project is mainly related to evaluation of total energy consumption of low energy house, the exterior envelope of which was wholly composed of structural insulated panels(SIP). The U-value of applied SIP was in the range of 0.189 to 0.269W/㎡․K and the U-value of pair glass from 0.78 to 1.298W/㎡․K was applied for window dependent to its function respectively. For comparison of total energy performance, the energy simulation for pilot house was performed to compare with the control house having insulation criteria of Korean building regulation in 2009. Based on simulation of dynamic energy performance, the pilot house saved 48.3% of annual energy consumption while the control house in 2009 consumed as 85.7GJ/y. In case of heating, the result showed that the energy saving ratio amounted to 76.7%. For CO₂ emission, the pilot house diminished approximately 35.4% from 6,208.4kgCO₂ to 4,009.2kgCO₂. In payback period to early investment, it was analyzed the pilot house took 7.8 years, when the low energy house built by other insulation method with same thermal perfusion took 11.5 years. From this result, it is considered that the SIP is more effective, economic to Green Home application.
참고 자료
없음