마찰진자시스템의 강성중심 변화에 따른 면진된 원전 구조물의 지진응답평가
(주)코리아스칼라
- 최초 등록일
- 2023.04.05
- 최종 저작일
- 2017.11
- 11페이지/ 어도비 PDF
- 가격 4,200원
* 본 문서는 배포용으로 복사 및 편집이 불가합니다.
서지정보
ㆍ발행기관 : 한국지진공학회
ㆍ수록지정보 : Jorunal of the Earthquake Engineering Society of Korea / 21권 / 6호
ㆍ저자명 : 석철근, 송종걸
영어 초록
In order to improve the seismic performance of structures, friction pendulum system (FPS) is the most commonly used seismic isolation device in addition to lead rubber bearing (LRB) in high seismicity area. In a nuclear power plant (NPP) with a large self weight, it is necessary to install a large number of seismic isolation devices, and the position of the center of rigidity varies depending on the arrangement of the seismic isolation devices. Due to the increase in the eccentricity, which is the difference between the center of gravity of the nuclear structure and the center of stiffness of the seismic isolators, an excessive seismic response may occur which could not be considered at the design stage. Three different types of eccentricity models (CASE 1, CASE 2, and CASE 3) were used for seismic response evaluation of seismically isolated NPP due to the increase of eccentricity (0%, 5%, 10%, 15%). The analytical model of the seismic isolation system was compared using the equivalent linear model and the bilinear model. From the results of the seismic response of the seismically isolated NPP with increasing eccentricity, it can be observed that the effect of eccentricity on the seismic response for the equivalent linear model is larger than that for the bilinear model.
참고 자료
없음
"Jorunal of the Earthquake Engineering Society of Korea"의 다른 논문