학교건축물 내 석면해체·제거공정 완료 후 공기 중 석면 연구
* 본 문서는 배포용으로 복사 및 편집이 불가합니다.
서지정보
ㆍ발행기관 : 한국냄새환경학회
ㆍ수록지정보 : 실내환경 및 냄새 학회지 / 22권 / 1호
ㆍ저자명 : 김지성, 임기교, 이지영, 원선정, 배정은, 양마란, 이준연, 배일상, 권승미, 신진호, 신용승, 김광래, 정숙녀
ㆍ저자명 : 김지성, 임기교, 이지영, 원선정, 배정은, 양마란, 이준연, 배일상, 권승미, 신진호, 신용승, 김광래, 정숙녀
목차
Abstract1. 서 론
2. 재료 및 방법
2.1 시료 채취 대상 및 방법
2.2 투과전자현미경 분석
2.3 위상차현미경 분석
3. 결과 및 고찰
3.1 석면 해체제거공정 완료 후 공기 중 석면 검출 현황
3.2 석면 해체제거공정 완료 후 검출된 공기 중 석면의 특징(1); 석면의 종류 및 구조
3.3 석면 해체제거공정 완료 후 검출된 공기 중 석면의 특징(2); 석면의 크기
4. 결 론
References
영어 초록
Following the social requirement to strengthen field supervision of the asbestos containing materials (ACM) abatement process with regard to asbestos school buildings, this study was conducted to understand the status and characteristics of airborne asbestos that may potentially occur after the ACM abatement process is completed. In the area where a series of asbestos abatement processes were finally completed, comprehensive area air sampling was performed. For sample analysis, Transmission Electron Microscopy (TEM) was used according to The Asbestos Hazard Emergency Response Act (AHERA) method and Phase Contrast Microscopy (PCM) analysis was also performed. Airborne asbestos was detected in 29.5% of the total samples, and the average concentration was 0.0039 ± 0.0123 s/cc (12.3 ± 38.9 s/mm2). 4.5% of the total samples exceeded the AHERA standard (70.0 s/mm2) and the average concentration was 0.0528 ± 0.0256 s/cc (167.2 ± 82.0 s/mm2). Airborne asbestos was no longer detected at the point when AHERA is exceeded after re-cleaning. Most of the detected asbestos was chrysotile (94.4%) and the structure types of asbestos were Matrix (41.4%), Fiber (39.9%), Bundle (10.8%), and Cluster (7.8%). Among the asbestos structures detected through transmission electron microscope analysis, the asbestos structures satisfying PCM-equivalent structures were found to be 6% of the detected asbestos, indicating that there is a limitation of the PCM analysis to check the airborne asbestos in that area. As a result of reviewing the status of airborne asbestos that may potentially occur and the type and dimensions of asbestos structure detected in the area, since the airborne asbestos exposure caused by poor field supervision for the ACM abatement process could not be ruled out, thorough management is necessary. In addition, the result of this study could be used as scientific evidence for establishing and strengthening policies related to ACM abatement, including cases of school buildings.참고 자료
없음"실내환경 및 냄새 학회지"의 다른 논문
- 축사 악취 특성 및 관리 (II) : 악취 배출 특성8페이지
- 축사 악취 특성 및 관리 (I) : 국내 축산업 현황, 악취 민원 및 관리 정책11페이지
- 연구실 환경에서 화상병균 소독을 위한 자외선 조사 효과 분석7페이지
- 산업단지 업종별 악취 배출특성 분석 및 적정방지기술 도출13페이지
- 아세트알데하이드 제어를 위한 굴패각 활용 흡착제 제조 연구7페이지
- 바이오커튼의 암모니아 감소 효과9페이지
- 서울시 내 산후조리원과 노인요양시설의 실내공기질 현황 및 폼알데하이드 노출로 인한 건강위해성평가8페이지
- 알루미늄 스틱 커튼월시스템의 열성능 평가12페이지
- 국내 COVID-19 추이 분석을 통한 정량적 연구필요성의 종합적 고찰11페이지
- 국내 일부 취약지역 거주 주민들의 체내 중금속 농도에 관한 연구10페이지