목차
1. Current situation of insulin DDS2. Design of our product
3. Principle of our patch
4. Economical evaluation
5. Business analysis
6. Reference
본문내용
1. Side effect1) Insulin using injection
Low blood sugar
Increase weight
Denaturation of skin
2) Insulin using pump
Easy to infection
Expensive
Need outer electric source
참고 자료
Xianhua Liu, et al. (2013) A One-compartment direct glucose alkaline fuel cell with methyl viologen as electron mediator. Applied Energy. 106 : 176 - 183Arthur Oubrie et al. (1999) Active-site structure of the soluble quinoprotein glucose dehydrogenase complexed with methylhydrazine A covalent cofactorinhibitor complex. PNAS. 96(21) : 11787 - 11791
Anne De Poulpiquet, et al. (2013) Carbon Nanotube-Enzyme Biohybrids in a Green Hydrogen Economy. Nanotechnology and Nanomaterials. chapter 19 : 433 - 466
Yan Wang, Yongjian Yao. (2012) Direct electron transfer of glucose oxidase promoted by carbon nanotubes is without value in certain mediator-free applications. Michochim Acta. 176 : 271 - 277
Alan Le Goff, et al. (2011) Enzymatic biosensors based on SWCNT-conducting polymer electrodes. Analyst 136 : 1279 - 1287
Fuyuki Sato, et al. (2005) Enzyme-based glucose fuel cell using Vitamin K3-immobilized polymer as an electron mediator. Electrochemistry Communications 7 : 643 - 647
Koen Besteman, et al. (2003) Enzyme-Coated Carbon Nanotubes as Single-Molecule Biosensors. Nano Letters 3(6) 727 - 730
Yueche Lin, et al. (2003) Glucose Biosensors Based on Carbon Nanotube Nanoelectrode Ensembles. Nano Letters 4(2) : 191 - 195
Mehrdad Hamidi, et al. (2008) Hydrogel nanoparticles in drug delivery. Advanced Drug Delivery Reviews 60 : 1638 - 1649
Yudai Ogawa, et al. (2015) Organic Transdermal Iontophoresis Patch with Built-in Biofuel Cell. Adv. Healthcare Mater. 4 : 506 – 510
Nakissa Sadrieh, (2009) Challenges in the development of transdermal drug delivery systems. U.S. FDA
Moncy V. Jose, et al. (2012) Direct electron transfer in a mediator-free glucose oxidasebased carbon nanotube-coated biosensor. Carbon. 50 : 4010 – 4020
Victtoria Flexer, et al. (2011) Efficient Direct Electron Transfer of PQQ-glucose Dehydrogenase on Carbon Cryogel Electrodes at Neutral pH. Analytical chemistry. 83 : 5721 – 5727
Arun Verma, et al. (2014) Emerging Trends in Noninvasive Insulin Delivery. Journal of Pharmaceutics : 9 pages
Maciej Karaskiewicz, et al. (2012) Fully enzymatic mediatorless fuel cell with efficient naphthylated carbon nanotube–laccase composite cathodes. Electrochemistry Communications. 20 : 127 – 127
Mark R Prausnitz, Robert Langer. (2008) Transdermal drug delivery. Nature Biotechnology. 26(11) : 1261 - 1267
김인태, et al. (2014) 바이오센서 적용을 위한 미생물이 고정된 부양형 탄소나노튜브 필름 제작과 유기인 화합물 검출. Journal of Sensor Science and Technology. 23(1) : 35 - 41
한세광. 약물전달시스템의 개발현황 및 전망. 포항공과대학교
고현아, et al. (2013) 천연 고분자가 함유된 락타이드 글리콜라이드 공중합체 필름에서 슈반세포의 부착과 증식 거동 비교평가. Polymer(Korea). 38(2) : 164 – 170
보건산업기술이전센터. (2012) 약물전달시스템 시장.
임화경. (2009) 의약품 허가 및 임상시험 승인 절차. 식품의약품안전평가원
김성학. (2001) 이온도입법의 진통효과. 대한물리치료학회지 13(3) : 815 - 820